The scope of this project is the capacity upgrade of the existing infrastructure of Kaiafa’s Thermal Spring Park at west Peloponnese. The Kaiafa’s complex, 3.67km² total area, included the facilities of thermal baths and the hotels on the island of St Cathrine. Project interventions consisted of preliminary and detailed design study of the water supply and sanitation networks of the existing facilities along with the future accomodation proposed by the Master Plan of the park .The total number of visitors is estimated at 1000 c/day in high season.The water supply transmission and distribution network consisted of 116km total length and a tank 500m³ volume. The sewerage ssytem included a PVC network of approximate 5Km pipes, six pumping stations and a new WWTP to serve 1000 PE.